Glossary

Fire protection inspection and back-office glossary

42 terms in plain language, written in our own words. For official definitions, see the adopted code.

Accounts receivable aging
A report showing unpaid invoices grouped by how long they have been outstanding.
Adopted edition
The specific edition of a code that a state or town has made law. It may be older than the newest edition.
Authority having jurisdiction
The office or official that enforces the fire code for a building, usually the local fire marshal or building official, sometimes an insurer. Often shortened to AHJ.
Backflow preventer
A valve assembly that keeps sprinkler water from flowing back into the drinking water supply.
Churn test
Running a fire pump without flowing water to confirm it starts and runs normally. Also called a no-flow test.
Contractor license
A license that lets a person or business contract for and supervise fire protection work.
Control valve
A valve that turns the water supply to a sprinkler system on or off.
Critical deficiency
A deficiency that could affect how the system performs in a fire, even though it is still in service.
Deficiency
A condition found during inspection or testing that needs correcting.
Deluge system
A system with open sprinklers or nozzles; when its valve opens, water flows from all of them at once.
Dry pipe sprinkler system
A system whose pipes hold pressurized air or nitrogen; water enters only after a sprinkler opens. Used where pipes could freeze.
Fire alarm control unit
The panel that receives signals from devices and triggers alarms and notifications.
Fire department connection
The outside inlet the fire department uses to pump extra water into a sprinkler or standpipe system.
Fire marshal
The local or state official responsible for fire code enforcement and fire investigations.
Fire pump
A pump that boosts water pressure for a fire protection system. It can be electric or diesel.
Fire watch
People assigned to patrol a building and watch for fire while protection is impaired.
Follow-up sequence
A planned series of reminders sent after a proposal until the customer answers.
Grease buildup inspection
Checking a kitchen exhaust system for grease deposits to decide whether it needs cleaning.
Hydrostatic test
Pressure testing a cylinder or piping with water to confirm it is sound.
Impairment
A condition where all or part of a system is out of service. It can be planned or an emergency.
Inspection
A visual check that equipment is in place, undamaged and in normal condition.
Inspection, testing and maintenance
The three kinds of ongoing work codes require to keep fire protection systems reliable. Often shortened to ITM.
Inspector's test connection
A valve at the far end of a system used to simulate one sprinkler flowing and test the alarm.
Journeyperson license
A license for an individual trade worker who works under a licensed contractor. Some states say journeyman.
Main drain test
Flowing water through the main drain to check the water supply against earlier results.
Maintenance
Work done to keep equipment working, such as servicing, cleaning or replacing parts.
National Fire Protection Association
A nonprofit that publishes widely adopted fire and life safety codes and standards, such as NFPA 25 and NFPA 72.
NFPA 10
The standard for portable fire extinguishers, including inspection, maintenance and hydrostatic testing.
NFPA 25
The standard for inspecting, testing and maintaining water-based fire protection systems such as sprinklers, standpipes and fire pumps.
NFPA 72
The national fire alarm and signaling code, including how alarm systems are inspected and tested.
NFPA 96
The standard for ventilation control and fire protection of commercial cooking operations (kitchen hoods and exhaust).
Noncritical deficiency
A deficiency that needs correcting but would not stop the system from working.
Notification appliance
A horn, strobe or speaker that warns occupants.
Preaction system
A system that needs a detection signal before water enters the pipes, often used where accidental discharge would be costly.
Repair proposal
A written quote to the building owner listing deficiencies, the repairs and the price. Sometimes called a deficiency quote.
Report submission portal
An online system some towns require contractors to use to file inspection reports.
Sensitivity test
A check that a smoke detector responds within its listed range of smoke density.
Standpipe
Piping with hose connections in stairwells or floors for firefighters to connect hoses.
Supervisory signal
An alarm panel signal that something needs attention, such as a closed valve, but is not a fire.
Testing
Operating equipment to prove it works, such as flowing water or setting off a detector.
Waterflow alarm
A device that signals when water is flowing in a sprinkler system.
Wet pipe sprinkler system
A system whose pipes are always full of water, so water flows as soon as a sprinkler opens.

Related: inspection frequency lookup, deficiency severity guide.